BN Business News
Ajouter votre entreprise →
Cette traduction est en cours de préparation. En attendant, nous affichons temporairement la version originale en anglais.

Entreprise · 08/04/20101 min de lecture

Airworthiness Directives; The Boeing Company Model 777-200, -200LR, -300, and -300ER Series Airplanes

Traduction automatique locale · Langue originale de la source

Résumé

We propose to adopt a new airworthiness directive (AD) for certain Model 777-200, -200LR, -300, and -300ER series airplanes. This proposed AD would require removing and repairing the sealant at the four lower corners of the wing center section and the four lower t- chord segment gaps on each side of the wing center section. This proposed AD results from reports of fuel leakage from the center tank. We are proposing this AD to detect and correct improperly applied sealant, which could result in the disbonding and displacing of sealant, and consequent fuel leaks. On the ground, uncontained fuel leakage could result in pooling, and pooling combined with an ignition source could result in a fire.

Langue originale de la source: Federal Register — Transportation DepartmentOuvrir le communiqué original →

Explorer les analyses

Analyses business →