Energia i regulacje · 12.03.2015
Entergy Nuclear Operations, Inc., Pilgrim Nuclear Power Station
The U.S. Nuclear Regulatory Commission (NRC) is considering issuance of an amendment to Renewed Facility Operating License No. DPR- 35, issued to Entergy Nuclear Operations, Inc., for operation of the Pilgrim Nuclear Power Station. The proposed amendment would modify the Safety Limit Minimum Critical Power Ratio from >= 1.08 to >= 1.10 for two recirculation loop operation and from >= 1.11 to >= 1.12 for single loop operation.